Following the International Electrotechnical Commission (IEC) in December 2014 formally promulgated safety standard dual side LED lamps IEC 62776 (ed.1.0): after 2014; the EU in April 2015 released EN 62776: 2015 standard. At this point, double-end LED lamps into the EU safety standards are unified.
New Standard Scope:
Double input for direct replacement of traditional fluorescent tubes, and that such replacement does not involve changes to the line inside the lamp;
G5 or G13 lamp;
Power not exceeding 125 W;
Input voltage does not exceed 250 V.
NOTE: improved LED lamp, not within the scope of the assessment criteria.
Request:
Labeling requirements: the need for labeling is compatible with conventional rectifier? Apply to frequency lighting ballasts? It is suitable for high frequency lighting ballasts?
Specification requirements: the need for clear and detailed lamp replacement instructions.
The main testing requirements:
Size and gauge requirements: Dimensions need to meet the requirements of the standard tube size; in predictable high temperature, low temperature environment, still meet the standard size.
Replace security requirements: After lamps directly replace traditional fluorescent tubes, does not affect the safety of the lamp.
Photobiological safety requirements: LED lamp product users will not be additional UV, blue and other injuries.
China test detected a Chinese LED leader in the field, but also as the largest set of safety, EMC, reliability, failure analysis program stop service third-party testing group, has been committed to providing customers with comprehensive professional and efficient product solutions.
The new standard was formally promulgated in April 2015, you can always contact us to upgrade. If you have any questions about the new standards, you can feel free to call or e-mail consultation.
- 當前位置: 首頁>>News>>Industry news